Another way to save money here is to build storage under the couches in the
living room just as we did with the beds described earlier . By building this type of
couch / storage space yourself , you can save a large amount of what is normally
...
Another way to save money here is to build storage under the couches in the
living room just as we did with the beds described earlier . By building this type of
couch / storage space yourself , you can save a large amount of what is normally
...
˹éÒ 314
The usual temperature for domestic hot water is 130° to 140°F . From an
engineering standpoint , it is better to separate the collector from the water
storage unit in order to maintain these temperatures with low thermal loss . With
the collector ...
The usual temperature for domestic hot water is 130° to 140°F . From an
engineering standpoint , it is better to separate the collector from the water
storage unit in order to maintain these temperatures with low thermal loss . With
the collector ...
˹éÒ 324
IMPORTANT : The bottom of the storage tank must be at least 1 foot above the
top of the collector ! Two to 10 feet is even better . A second frequent problem for
thermosyphon systems is air being trapped in the piping systems . Water at 32°F
...
IMPORTANT : The bottom of the storage tank must be at least 1 foot above the
top of the collector ! Two to 10 feet is even better . A second frequent problem for
thermosyphon systems is air being trapped in the piping systems . Water at 32°F
...
¤ÇÒÁ¤Ô´àË繨ҡ¼ÙéÍ×è¹ - à¢Õ¹º·ÇÔ¨Òóì
Review: Low-Cost, Energy-Efficient Shelter for the Owner and Builder
º·ÇÔ¨Òóì¨Ò¡¼Ùéãªé - Myles Blackwood - Goodreadsold school book on ways to save energy, and live a life that uses less energy. it's a bit dated, so... i can think of a few things off the top of my head that should probably be updated.... however, for a $2 used book, it was worth it. ÍèÒ¹¤ÇÒÁ¤Ô´àË繩ºÑºàµçÁ
à¹×éÍËÒ
Housing Options TodayJerome Kerner8 | 8 |
Financing Your Shelter NeedsChris Ahrens14 | 14 |
Some Problems To OvercomeCodes Appeals Public Acceptance | 31 |
ÅÔ¢ÊÔ·¸Ôì | |
9 à¹×éÍËÒÍ×è¹æ äÁèä´éáÊ´§äÇé
©ºÑºÍ×è¹æ - ´Ù·Ñé§ËÁ´
¤ÓáÅÐÇÅÕ·Õ辺ºèÍÂ
added addition allow applied basic beam blocks building ceiling Chapter codes cold collector complete concrete consider construction contractor cooling cost cover curtain doors effect efficient electric energy example existing expensive exterior feet FIGURE finish floor flow foot foundation frame glass greenhouse heat heater hot water important inches inside install insulation interior keep less light living loan look lower materials natural operating overhang panels percent plans plastic possible problems protection resistance roof shade side slope soil solar space square standard storage structure studs summer sure surface tank temperature trees unit usually ventilation vents wall wind winter wood