Passive Solar House BasicsAncient City Press, 1995 - 136 หน้า Anyone who has been in a solar house, on a cold winter day has felt thearmth and comfort of its natural radiant heat. In 1958, solar pioneer Peteran Dresser built his first solar-heated house, one of the two oldest in thenited States. In this book van Dresser lays out in text and illustration therinciples an owner builder will need to know in siting, designing, buildingnd living in their solar house. Several sample house plans, ideas for solarot water heaters, and plans for solar crop dryers give the solar enthusiasthe basic information they will need to begin plans on their efficient home.his book shows that solar energy can be economically harnessed by simpleeans. Means that are within the grasp of the average homeowner and builder. |
จากด้านในหนังสือ
ผลการค้นหา 1 - 3 จาก 18
หน้า 38
... floor in such a structure receives much of the incoming sunlight . It is therefore logical to delib- erately design this floor as one of the prime absorbers and storers of sun - generated heat . Again , for this purpose , a tradi ...
... floor in such a structure receives much of the incoming sunlight . It is therefore logical to delib- erately design this floor as one of the prime absorbers and storers of sun - generated heat . Again , for this purpose , a tradi ...
หน้า 40
... floor mass and sealed off from it by a heavy - duty membrane of plastic . The tops of the con- crete stem walls on which the adobe wall blocks are laid should be sealed with asphalt to prevent capillary action from drawing moisture up ...
... floor mass and sealed off from it by a heavy - duty membrane of plastic . The tops of the con- crete stem walls on which the adobe wall blocks are laid should be sealed with asphalt to prevent capillary action from drawing moisture up ...
หน้า 129
... floor area , and range of interior tem- perature variations . This table indicates a somewhat closer matching of the ... Floor Area 566'2 566'2 588'2 574'2 Glazing Area 19'2 148'2 134'2 217'2 Glazing / Floor Ratio .03 .26 23 38 Inside ...
... floor area , and range of interior tem- perature variations . This table indicates a somewhat closer matching of the ... Floor Area 566'2 566'2 588'2 574'2 Glazing Area 19'2 148'2 134'2 217'2 Glazing / Floor Ratio .03 .26 23 38 Inside ...
เนื้อหา
Solar Energy A Natural for the Southwest | 21 |
Saving Fuel at the Home Front | 23 |
Some Principles of Climatic Adaptation | 26 |
ลิขสิทธิ์ | |
18 เนื้อหาอื่นๆ ไม่ได้แสดงไว้
คำและวลีที่พบบ่อย
absorb ADOBE WALL antifreeze Appendix Arizona Arizona State University Aubrey Owen B. T. Rogers bedrooms building built ceiling circulation clerestory Climatic collector panel construction convection cool air Corners Regional Commission costs Crop Drier cross section direct gain double-glazed Dresser House drying ducts dwelling efficient energy-conserving ergy exposure exterior Fiberglas Figure fireplace floor Four Corners Regional Francis Wessling fuel furnace Ghost Ranch glazing greenhouse harvest kitchen heating requirements home builder house design installation insulating interior low winter sun Mexico Solar Energy night passive solar Peter van Dresser PUMICE Quentin Wilson Rio Arriba County roof Santa Fe shutters slope Solar Energy Association solar heating SOLAR HOUSE solar input solar radiation solar water heaters solar windows south facade south wall south-facing space store heat summer Sundwellings team suntempered surface temperature therms tion traditional Trombe wall unit vigas warmth weather well-insulated William Lumpkins winter wood burning