Low-cost, Energy-efficient Shelter for the Owner and BuilderEugene Eccli Rodale Press, 1976 - 408 ˹éÒ Learning how to repair, renovate, remodel and build to meet your housing needs as efficiently as possible can be a satisfying and money saving experience. |
¨Ò¡´éÒ¹ã¹Ë¹Ñ§Ê×Í
¼Å¡Òäé¹ËÒ 1 - 3 ¨Ò¡ 47
˹éÒ 157
... cold air must be heated . Yet a third reason is that the cold , dry outside air is excluded so it doesn't have the effect of lowering the humidity inside . Cold air has a much lower humidity content than warm air . If the infiltrated ...
... cold air must be heated . Yet a third reason is that the cold , dry outside air is excluded so it doesn't have the effect of lowering the humidity inside . Cold air has a much lower humidity content than warm air . If the infiltrated ...
˹éÒ 200
... cold air infiltration , then tack over the frame a plastic sheet like the ones mentioned before for storm windows . A curtain or drape can be hung in front of the door and makes a pleasant appearance . Air - Lock Foyer Once you've ...
... cold air infiltration , then tack over the frame a plastic sheet like the ones mentioned before for storm windows . A curtain or drape can be hung in front of the door and makes a pleasant appearance . Air - Lock Foyer Once you've ...
˹éÒ 353
... Cold air return at furnace base and from each corner of the house . Cold air duct shall consist of 1 / 8 - inch transite covered joist spaces along outside walls and connection to 10 - inch- diameter or 6 X 12 - inch rectangular ...
... Cold air return at furnace base and from each corner of the house . Cold air duct shall consist of 1 / 8 - inch transite covered joist spaces along outside walls and connection to 10 - inch- diameter or 6 X 12 - inch rectangular ...
à¹×éÍËÒ
Housing Options TodayJerome Kerner8 | 8 |
Financing Your Shelter NeedsChris Ahrens14 | 14 |
Some Problems To OvercomeCodes Appeals Public Acceptance | 31 |
ÅÔ¢ÊÔ·¸Ôì | |
12 à¹×éÍËÒÍ×è¹æ äÁèä´éáÊ´§äÇé
©ºÑºÍ×è¹æ - ´Ù·Ñé§ËÁ´
¤ÓáÅÐÇÅÕ·Õ辺ºèÍÂ
air infiltration applied asphalt shingles attic basement basic BEDROOM blocks building caulking ceiling Chapter chimney clerestories climate codes cold collector concrete construction contractor cost curtain doors duct efficient electric energy energy conservation expensive exterior fiberglass FIGURE finish floor flow foundation frame gallons glass greenhouse heat exchanger heat loss heating system horizontal inches inside install insulation interior joists kitchen light living loan lumber masonry materials Mineral wool moisture overhang panels percent pipe plans plastic plumbing plywood Polystyrene polyurethane possible post and beam problems renovate roof roughsawn sash seal shade side slab slope soil solar windows space square feet Steve Baer storage tank storm windows structure studs styrofoam summer surface temperature thermostat thermosyphon tion total resistance trees unit usually vapor barrier ventilation vents vertical wall weatherstripping wind window area winter wood