¨Ò¡´éÒ¹ã¹Ë¹Ñ§Ê×Í
¼Å¡Òäé¹ËÒ 1 - 3 ¨Ò¡ 44
˹éÒ 27
A typical repayment schedule for construction would be as follows : 1st Payment -
Rough Enclosure - 30 percent of the loan The building should be framed and
sheathed , the roof completed , and window and exterior door frames set .
A typical repayment schedule for construction would be as follows : 1st Payment -
Rough Enclosure - 30 percent of the loan The building should be framed and
sheathed , the roof completed , and window and exterior door frames set .
˹éÒ 181
In newer windows , the casing and sash are usually a single unit and should
come out as one piece . In some situations this window unit will be set in under
the exterior siding , and removing some of this siding will be necessary . Once the
...
In newer windows , the casing and sash are usually a single unit and should
come out as one piece . In some situations this window unit will be set in under
the exterior siding , and removing some of this siding will be necessary . Once the
...
˹éÒ 351
Vapor barrier to be 6 - mil polyethylene . Siding . Panel siding at gable ends shall
be 3 / 8 - inch thick and 4 - foot wide exterior - grade plywood in roughsawn
pattern with 1 X 2 - inch batten at each stud . Remaining walls shall be panel
siding ...
Vapor barrier to be 6 - mil polyethylene . Siding . Panel siding at gable ends shall
be 3 / 8 - inch thick and 4 - foot wide exterior - grade plywood in roughsawn
pattern with 1 X 2 - inch batten at each stud . Remaining walls shall be panel
siding ...
¤ÇÒÁ¤Ô´àË繨ҡ¼ÙéÍ×è¹ - à¢Õ¹º·ÇÔ¨Òóì
Review: Low-Cost, Energy-Efficient Shelter for the Owner and Builder
º·ÇÔ¨Òóì¨Ò¡¼Ùéãªé - Myles Blackwood - Goodreadsold school book on ways to save energy, and live a life that uses less energy. it's a bit dated, so... i can think of a few things off the top of my head that should probably be updated.... however, for a $2 used book, it was worth it. ÍèÒ¹¤ÇÒÁ¤Ô´àË繩ºÑºàµçÁ
à¹×éÍËÒ
Housing Options TodayJerome Kerner8 | 8 |
Financing Your Shelter NeedsChris Ahrens14 | 14 |
Some Problems To OvercomeCodes Appeals Public Acceptance | 31 |
ÅÔ¢ÊÔ·¸Ôì | |
12 à¹×éÍËÒÍ×è¹æ äÁèä´éáÊ´§äÇé
©ºÑºÍ×è¹æ - ´Ù·Ñé§ËÁ´
¤ÓáÅÐÇÅÕ·Õ辺ºèÍÂ
added addition allow applied basic beam blocks building ceiling Chapter codes cold collector complete concrete consider construction contractor cooling cost cover curtain doors effect efficient electric energy example existing expensive exterior feet FIGURE finish floor flow foundation frame glass greenhouse heat heater hot water important inches inside install insulation interior keep kitchen less light living loan look lumber materials natural operating overhang panels percent plans plastic plywood possible problems protection resistance roof shade side slope soil solar space square standard storage structure studs summer sure surface tank temperature trees unit usually ventilation vents wall wind winter wood